Interface Select (DSW8). When OFF, the printer will activate the Parallel input
port for receiving data. When ON, the printer will activate the optional interface (if
any) that is installed.
ERROR DISPLAY
The ERROR dispay is a seven segment LED array that provides information on error
conditions detected by the printer. The conditions are:
LED ERROR
0 Flash Memory error.
1 Not Assigned
2 Motherboard error
3 EEPROM error
4 Electrical Head error
5 Head not latched in the down position
6 Out of Paper
7 Sensor type or level error
8 Cutter error
8. Program error
9 Ribbon End (TT mode only)
A Receive buffer overflow
b Parity error (Serial I/F only)
c Framing error (Serial I/F only)
d Overrun error (Serial I/F only)
E Time Out error
F Download Font/Graphic error
For more information the cause and troubleshooting of printer errors, see Section 6.
Troubleshooting.
DSW8 SETTING
Off Parallel I/F
On Optional I/F
12345678
ON
OFF
Configuration Switch
Section 2. Installation and Configuration
SATOCT SeriesPrinters9001069A Page2-15