7KVM Switches KVM0108A and KVM0116A User Manual
Installation
Overview
KVM adapter cables connect the KVM switch to the connected devices. A separate KVM adapter cable
is required for each computer or device connection.
See “KVM Server Modules and cables” on page 4 or contact APC Customer Support for
help.
Note: 1. See “Safety” on page 2 before installing the KVM switch.
2. Power to any device must be turned off before connecting. Unplug the power cords of any
computers that have the Keyboard Power On function.
Rack Mounting
Note: Allow at least 2 inches (5.1 cm) on each side for adequate ventilation and 5 inches
(12.7 cm) at the rear for power cord and cable clearance.
The switch can be mounted in a 19" (1U) rack. The mounting brackets can screw into the front or the
back of the unit so that it can be attached to the front or back of the rack.
Note: The standard rack mount kit package does not include rack mount screws or cage nuts.
If you need additional rack mount screws or cage nuts, contact your rack dealer. Use cage
nuts (not provided) for racks that are not pre-threaded.
Rack mounting
1. Position the switch in the front of the rack.
Align the mounting bracket holes with the
holes in the rack.
2. Secure the mounting brackets to the rack
with the screws (not supplied).
aem0372a