Section 2. Operating Procedures
14
4. Run the Laminator
1. Lower Draw Down Assembly and secure locking pins.
2. Align right and left Dam Stop brackets into position at the edges of the media.
The inner brackets align with the outer edges of the media and lock down by
turning the red knob on top of the bracket. The outer brackets position similarly
next to the inner brackets with the bracket roller sealing against the bottom of the
media. Tighten in place with the red knob on the side of the bracket.
3. Open the Flow Control valves on the applicator Nozzle and begin filling the
reservoir between the Dam Stops.
Figure 2.4 Applicator Nozzle
4. Once coating is spanning between the two dam stops, lower the Dryer Assembly
to the Down position.
5. Turn the Speed Control knob to the desired speed setting.