TROUBLESHOOTING AND MAINTENANCE
83
8
4
Raise the fusing unit release lever, close the front cover and
then close the side cover by pressing the round projections
near the side cover open button. The error indicator will go out
and the ready indicator will light up.
D: Misfeed in the RSPF
An original misfeed may occur at one of three locations: if the misfed original is
visible in the document feeder tray, (A) in the document feeder tray; if the misfed
original is not visible in the document feeder tray, (B) in the exit area or (C) under the
document feeder cover. Remove the misfed original following the instructions for
each location.
(A) Open the document feeder cover and pull the original gently to the left and
out from the document feeder tray. Close the document feeder cover. Open
and close the RSPF to clear the error indicator. If the misfed original cannot
be easily removed, proceed to (C).
(B) Open the RSPF and rotate the roller to remove the misfed original from the
exit area. If the misfed original cannot be easily removed, proceed to (C).
With the RSPF, pull out the reversing tray to remove the misfed original.
When closing the covers, be sure to close the front cover securely and
then close the side cover. If the covers are closed in the wrong order,
the covers may be damaged.
After removing a misfed original from the exit area of the RSPF, be sure
to insert the reversing tray into the exit area until it locks in place.
Caution
Document feeder cover
Roller
Note
Reversing tray