80
■
RSport(COM1,COM2)
Procedure
Program each item as follows:
•PORT1(Usetheselectiveentry)
EFT: EFT
ONLINE: On-line
SCANNER: Scanner
•PORT2(Usetheselectiveentry)
EFT: EFT
ONLINE: On-line
NOTE
For the Quebec scal type is as follows.
Procedure
Program each item as follows:
•PORT1(Usetheselectiveentry)
SRM: SRM (ECR → SRM → Printer)
CONTINUOUS: Disconnection of the SRM (ECR → Printer)
ONLINE: On-line
SCANNER: Scanner
•PORT2(Usetheselectiveentry)
SRM: SRM (ECR → SRM → Printer)
CONTINUOUS: Disconnection of the SRM (ECR → Printer)
ONLINE: On-line
■
On-line
Procedure
Program each item as follows:
The screen continues.
•TERMINALNo.(Usethenumericentry)
Terminal number (6 digits: 0 to 999999).
•CISIGNAL(Usetheselectiveentry)
Sensing of the CI signal
NON: Disables sensing of the CI signal
SENSING: Enables sensing of the CI signal
•LINEFORM(Usetheselectiveentry)
Programming of the modem control
FULL: Full duplex system
HALF: Half duplex system
•BAUDRATE(Usetheselectiveentry)
Transmission data rate
38400 bps 19200 bps
9600 bps 4800 bps
•STARTCODE(Usethenumericentry)
Start code (3 digits: 0 to 127)
•ENDCODE(Usethenumericentry)
End code (3 digits: 0 to 127)
•TIMEOUT(Usethenumericentry)
Programming of the time-out time (3 digits: 1 to 255 sec.)