21
Display as below:
C:\>arp -d
C:\>arp -s 192.168.1.61 00-0c-e8-00-00-01
C:\>ping -t 192.168.1.61
Pinging 192.168.1.61 with 32 bytes of data:
Request timed out.
Request timed out.
Request timed out.
Reply from 192.168.1.61: bytes=32 time=5ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Reply from 192.168.1.61: bytes=32 time=4ms TTL=255
Ping statistics for 192.168.1.61:
Packets: Sent = 7, Received = 4, Lost = 3 (42% loss),Approximate round
trip times in milli-seconds:
Minimum = 4ms, Maximum = 5ms, Average = 2ms
Control-C
^C
C:\>arp -d
C:\>exit
2 clear ARP: enter<arp d>.
3 Set up ARP: enter<arp s 192.168.1.61 00-0c-e8-00-00-01>.
4 PING: enter<ping t 192.168.1.61>.
5 Turn off the network camera.
6 Turn on the network camera again.
7 Enter Ctrl-c after Pinging, and enter <arp-d> to clear ARP
statistics.