MP 595 Modem User Guide
The low rate timer sets the interval at which reports are sent in
the absence of any other trigger or timer. It is in minutes with a
default of five minutes.
The fast rate timer only becomes active when an alarm
condition is triggered by a rise or drop in the level of one of the
digital I/O channels. The default for the fast rate timer is three
seconds.
Note: When the fast rate timer is set to 0, a single report is sent when
an I/O alarm is triggered.
If the GPS timer is set to a value other than 0, it controls the
frequency of reports in the absence of any alarm or event
triggers. (However, if the GPS timer is set to a longer interval
than the low rate timer, the value for the low rate timer will
determine report frequency.)
MP Modem
Host
Fast rate timer = 3 seconds
Low rate timer = 5 minutes
GPS timer = 10 seconds
TM_SUM_REG_IND
10 seconds
TM_SUM_REG_IND
10 seconds
TM_SUM_REG_IND
Digital I/O alarm
TM_SUM_REG_IND
3 seconds
TM_SUM_REG_IND
3 seconds
TM_SUM_REG_IND
52 2130795