Silex technology PRICOM C-6400W Printer User Manual


 
30Appendix
Users Manual CX2
Other functions
- For further details on how to use the PRICOM C-6400W Web browser, TELNET or the procedure
to change the PRICOM C-6400W configuration, refer to "Connect to the PRICOM C-6400W
from a Web browser" or "TELNET" in this section.
This chapter explains other functions about the PRICOM C-6400W. A web browser or TELNET
is required for configuration.
IP filtering
1. Log in to the PRICOM via a web
browser, then go to the "TCP/IP" tab.
2. Enter the necessary parameters at "IP
filter Configuration" in the "TCP/IP"
item. For this case, enable "ALLOW"
at the Filter Mode, then enter
192.168.20.1 and 192.168.20.50 for
both "Start Address" and "End
Address" area respectively.
The PRICOM can define scopes of IP addresses to allow or deny communication. When
setting up for "DENY", communications from the designated IP address scope will be prohibited.
When setting up "ALLOW", communication will be allowed only from the designated IP
addresses. Up to 4 IP address scopes can be registered for the DENY/ALLOW functions. IP
filtering can protect illegal access from unexpected network client users.
(Example)
To allow access from the IP address scope between 192.168.20.1-192.168.20.50 using a web browser;