Soehnle 2790 Postal Equipment User Manual


 
Messages
The scale sets the value
zero automatically when
it is switched on.
The zero range at power-
on is -5% ....+15% of the
weighing range.
If the scale is out
side the
set tolerance range, the
display shown adjacent
appears.
Parts weight too small
Zeroing not possible
Taring is not possible
Print not permitted on
over- or underload
Switch to lbs
deactivated
Elimination
! Either take the load off
the platform or press the
key to activate the cali-
brated zero point.
" There is a mechanical
or electrical fault.
The scale is not suitable
for these parts.
The zero limit has been
exceeded or undershot.
Cannot tare the zero
display or negative values.
Place an object on the
scale / remove an object
from the scale.
Activation is described on
Pages 18/19.
In case of other error mes-
sages, please contact your
SOEHNLE service
Technical data
• Housing made of anodised aluminium
• Protection class IP
65, dust-proof and splash-proof.
• Operated by means of a tactile keypad.
• Plug-in power supply 100-240V, 57-63Hz
• Operating temperature -10° ..... +40° C
• Storage temperature -20° ..... +60° C
• Zero range -1 %... +3 % of the weighing range (max.)
• Zero range at power-on -5% ...+15% of the weighing
range.
• RS 232 (V24) interface for printer or IT connection.
For a description of the interface, please contact your
Soehnle service partner.
!
"
77mm
82,6 mm
143,7 mm
306 mm
125 mm
20
ENGLISH