Sony VPL-AW10 Projector User Manual


 
53
Others
The ?/1 (On/standby) or LAMP/COVER indicator lights up or flashes if there is any
trouble with your projector.
When a warning indicator other than the above status, consult with Sony Customer Information
Service Center.
Warning Indicators
Symptom Cause and Remedy
LAMP/COVER flashes in
red. (A repetition rate of 2
flashes)
c Close the lamp cover securely, then tighten the screws securely.
(1 page 56)
c Close the air filter cover securely. (1 page 57)
LAMP/COVER flashes in
red. (A repetition rate of 3
flashes)
c The lamp has reached the end of its useful lifespan. Replace the
lamp. (1 page 55)
c The lamp has reached a high temperature. Wait until the lamp
cools, and then turn on the power again.
?/1 (On/standby) flashes
in red. (A repetition rate of
4 flashes)
c The fan is broken. Consult with qualified Sony personnel.
?/1 (On/standby) flashes
in red. (A repetition rate of
2 flashes)
c The internal temperature is unusually high. Check to ensure that
if nothing is blocking the ventilation holes or whether or not the
projector is being used at high altitudes.
?/1 (On/standby) flashes
in red. (A repetition rate of
6 flashes)
c Disconnect the AC power cord, then confirm the
?/1
(On/standby) lamp is turned off. Turn on the power again after
re-connecting it. If the indicators still light up, the electrical
system has a problem. Consult with qualified Sony personnel.
Note
LAMP/COVER indicator
?/1 (On/standby) indicator