Star Micronics NX-1000 Printer User Manual


 
OTHER PRINTER CONTROL COMMANDS
Set MSB to 7
Mode ASCII Decimal Hexadecimal
Both <ESC>
>
27 62 1B 3E
Sets the most significant bit of each subsequent byte received to 1, allowing
users with a 7-bit interface to access characters with ASCII codes greater
than 127.
Set MSB to 0
Mode
ASCII Decimal Hexadecimal
Std.
<ESC> “=”
27 61 1B 3D
IBM
<FS> “c”
28 61 IC 3D
Sets the most significant bit of each subsequent byte received to 0.
Accept MSB as is
Mode
1 ASCII 1 Decimal Hexadecimal
Both I
<ESC>
“#”
127 35 IlB 23
Cancels the preceding commands and accepts the most significant bit as
it is sent to the printer.
Delete last character sent
Mode 1 ASCII I Decimal Hexadecimal
Both
<DEL> 127 7F
Deletes the last character received. Ignored if the last character received
has already been printed, or if the last character received was all or part
of a command.
Cancel last line
-
Model ASCII
I Decimal
Both I <CAN> 1 24
I Hexadecimal
1 18
Deletes the last line currently present in the print buffer.