Star Micronics SP2000 Computer Monitor User Manual


 
24
FUNCTION
Sets vertical tab stops
CODE
<ESC> "B"
n1 n2
...nk <0>
(1B)H (42)H
n1 n2
...nk (00)H
DEFINITION RANGE
1
<
=
n1
<
=
n2
<
=
n3
... <
nk
<
=
255
<
=
1
<
=
k
<
=
16
OUTLINE
Cancels all current vertical tab stops and sets new vertical tab
stops at lines
n1
,
n2
, etc. where
n1
,
n2
, etc. are numbers
between 1 and 255. A maximum number of 16 vertical tab
positions can be set. Tab positions must be specified in
ascending order; any violation of ascending order terminates the
tab position list. Standard termination is by the <0> control code.
Vertical tab positions are set in terms of the current line spacing
and do not move if the line spacing is changed later.
NOTE
If a tab set position <nk> is equivalent or smaller than <nk -1> just
preceding the tab set position, setting of vertical tab is assumed
as complete.