Star Micronics TCP300II Series Printer User Manual


 
20
(15) 7 bit format third track data setting command (Model: 310)
This command sets the write data to the third track with a 7-bit format.
Excluding 02h (STX) and 03h (ETX), the write data string must be data from 01h to 7Eh in 0
to 69 bytes.
The starting and ending symbols, LRC and parity bit on the magnetic stripe are all
automatically applied. A reject response is issued when an error is detected in the write data.
Note that this command cannot be used with on models with one magnetic stripe (TCP300).
Command Transfer Formats
STX 3Ah Write data string ETX BCC
Response Transfer Formats
STX 3Ah Status ETX BCC
(16) First track data setting command (Model: 310)
This command sets the first track write data.
The magnetic format of the write data corresponds to the following formats, but the format that
is set abides by the content of the preset memory switches. See Model Setting Commands
(91h) for details.
• 7-bit format conforming to JISX6302
• Reverse 7-bit format Reverse direction writing format of the format above
• 6-bit format conforming to ISO 7811/2 first track
• 4-bit format conforming to ISO 7811/2 second and third tracks
However, the second track is in 70 bpi format.
The starting and ending symbols, LRC and parity bit on the magnetic stripe are all
automatically applied. A reject response is issued when an error is detected in the write data.
Command Transfer Formats
STX 3Bh Write data string ETX BCC
Response Transfer Formats
STX 3Bh Status ETX BCC