34 Netra CP2500 Board Programming Guide • March 2007
Using the show-sensors Command at the
OpenBoot PROM
The show-sensors command at OpenBoot PROM displays the readings of all the
temperature sensors on the board. A sample output for typical sensor readings for a
Netra CP2500 is as follows:
Environmental Monitoring Application
Programming
The following sections describe how to use the environmental monitoring functions
in an application program.
For the environmental monitoring application program (envmond) to monitor the
hardware environment, the following conditions must be met:
■ The system controller device driver must be installed.
■ The environmental monitoring application program (envmond) must be installed
and running.
ok show-sensors
Sensor# Sensor Name Sensor Reading
======= ==================================== ===================
1 EP 5v Sensor (d1) 4.968 volts
2 EP 3.3v Sensor (8b) 3.336 volts
3 BP +12v Sensor (ce) 11.760 volts
4 BP -12v Sensor (63) -12.010 volts
5 IPMB Power Sensor (d2) 4.968 volts
6 SMC Power Sensor (69) 2.448 volts
7 VDD 3.3v Sensor (a8) 3.2592 volts
8 VCCP Sensor (64) 1.1800 volts
9 +12v Sensor (ba) 11.6250 volts
a -12v Sensor (36) -12.040 volts
b +5v Sensor (be) 4.940 volts
c Standby 3.3v Sensor (be) 3.2680 volts
d Main 3.3v Sensor (be) 3.2680 volts
e External I temp (CPU) Sensor (3e) 62 degree C
f External II temp (Outlet) Sensor (20) 32 degree C
10 Internal temp (Inlet) Sensor (1d) 29 degree C
ok