Administrator Settings
167
TANDBERG Audio Science microphone elements: Audio Technica AT-861PZ and Crown PZM-
6D
Signal levels -
microphone
inputs
Clipping level Nominal level
Input menu level
settings
Vpp dBu dBu
0.0 dB
83.0 mVpp -28.4 dBu -46.4 dBu
1.5 dB
69.8 mVpp -29.9 dBu -47.9 dBu
3.0 dB
58.8 mVpp -31.4 dBu -49.4 dBu
4.5 dB
49.4 mVpp -32.9 dBu -50.9 dBu
6.0 dB
41.6 mVpp -34.4 dBu -52.4 dBu
7.5 dB
35.0 mVpp -35.9 dBu -53.9 dBu
9.0 dB
29.4 mVpp -37.4 dBu -55.4 dBu
10.5 dB
24.8 mVpp -38.9 dBu -56.9 dBu
12.0 dB
20.8 mVpp -40.4 dBu -58.4 dBu
13.5 dB
17.5 mVpp -41.9 dBu -59.9 dBu
15.0 dB
14.8 mVpp -43.4 dBu -61.4 dBu
16.5 dB
12.4 mVpp -44.9 dBu -62.9 dBu
18.0 dB
10.4 mVpp -46.4 dBu -64.4 dBu
19.5 dB
8.8 mVpp -47.9 dBu -65.9 dBu
21.0 dB
7.4 mVpp -49.4 dBu -67.4 dBu
22.5 dB
6.2 mVpp -50.9 dBu -68.9 dBu
Table1: Signal Levels - Microphone inputs