TANDBERG GW Data port Command Interface User Guide
9
4.2.1. System Configuration Commands
Command: Description:
H323Gatekeeper
Sets gatekeeper parameters.
NOTE! H.323 services must be set before the GW can be registered to a
gatekeeper.
H323Gatekeeper Address <IPAddr>
or
H323Gatekeeper Authentication Mode <Auto/off>
or
H323Gatekeeper Authentication ID: <S: 0, 50>
Or
H323Gatekeeper Authentication Password: <S: 0, 50>
---
sub-commands:
• Authentication Mode configures the use of authentication
against a gatekeeper.
• Authentication ID Configures the user name used within an
authentication challenge
• Authentication Password sets the password used within the
authentication process.
NOTE! Authentication Password is write only.
Example of H323Gatekeeper feedback:
Xconf H323Gatekeeper Authentication
*c xConfiguration H323Gatekeeper Authentication Mode: Off
*c xConfiguration H323Gatekeeper Authentication ID: ""
H323CallSetup
Configures for direct or via gatekeeper calling
H323CallSetup Mode: <Direct/Gatekeeper>
--
Example of H323CallSetup feedback:
*c xConfiguration H323CallSetup Mode: Direct
IP
Configures the LAN interfaces when static IP address allocation is used.
NOTE! The GW needs to reboot before the changes will take effect.
IP Assignment: <DHCP/Static>
or
IP Address <IPAddr>
or
IP Address Subnetmask <Subnetmask>
or
IP Address Gateway <IPAddr>
or
IP Address DNS Server [1..5] Address <IPAddr>
or
IP Address DNS Domain Name <S: 0, 64>
---
parameters: