TANDBERG Video Portal Data port Command Interface User Guide
Status format:
<ProductType>
<Uptime>
<Software
Version>
Name>
ReleaseDate>
Configuration
Telephony:>
VideoTelephony:>
<Hardware :
Version>
SerialNumber>
MainBoard>
AdditionalBoard>
Configuration:
PRI>
TemperatureCelcius>
TemperatureFahrenheit>
---
Parameters:
• ProductType, the name of the product, e.g. Video Portal
• Uptime, the time the system is running since the last reboot in seconds
• Software
o Version, the unique name of the software
o Name,
o ReleaseDate, the time and date of the build of this software
o Configuration
• Telephony, the amount of supported voice channels
• VideoTelephony, the amount of supported video channels
• Hardware
o Version, software ID
o SerialNumber, software serial number
o MainBoard, the ID of the main board
o AdditionalBoard, indicates extra boards in the box
o Configuration:
• PRI, the amount of PRIs in the target system
• BRI, the amount of BRIs in the target system
• TemperatureCelcius, temperature of the main board in Celcius
• TemperatureFahrenheit, temperature of the main board in Fahrenheit
Example of SystemUnit feedback:
*s SystemUnit:
ProductType: "TANDBERG Video Portal"
Uptime: 15123
Software:
Version: "R3.0Beta2 (TEST SW)"
Name: "test"
ReleaseDate: "2007-03-21, 17:54"
Configuration:
Telephony: 0
VideoTelephony: 0
Hardware:
Version: "EP 1.0"
SerialNumber: "43A00001"
MainBoard: ""
AdditionalBoard: ""
D1392602 25