TANDBERG MXP Projector User Manual


 
TANDBERG Maestro MXP
242
5.1.4 Data port
The data port(s) are implemented as Data Communications Equipment (DCE). The connectors
used are female 9-pin D-subs.
The TANDBERG main camera is normally connected to data port 2 and pin number 4 provides
12V DC / 1 Amps to the main camera. Otherwise the pin-outs for both data ports are the same.
Signal name Direction Pin
number
Carrier detect, CD From
DCE
1
Receive data,
RXD
From
DCE
2
Transmit data,
TXD
To DCE 3
Data terminal
ready, DTR
From
DCE
4
Signal ground,
GND
5
Data set ready,
DSR
From
DCE
6
Ready to send,
RTS
To DCE 7
Clear to send,
CTS
From
DCE
8
Ring indicator, RI From
DCE
9