Appendix A: Specification
s
PS280 & PS283 User Manual
27
Table 4: Electrical Characteristics
Characteristic Measurement
Line voltage 90 to 110
108 to 132
198 to 242
216 to 250, all VAC at 50–60 Hz
Power consumption 386 VA, 300 W maximum (PS280)
265 VA, 200 W maximum (PS283)
Table 5: Certifications and Compliances
EC Declaration of
Conformity – EMC
Meets intent of Directive 89/336/EEC for Electromagnetic
Compatibility. Compliance was demonstrated to the following
specifications as listed in the Official Journal of the European
Communities:
EN 55011 Class B Radiated and Conducted Emissions
EN 50081-1 Emissions:
EN 60555-2 AC Power Line Harmonic Emissions
EN 50082-1 Immunity:
IEC 801-2 Electrostatic Discharge Immunity
IEC 801-3 RF Electromagnetic Field Immunity
IEC 801-4 Electrical Fast Transient/Burst Immunity
IEC 801-5 Power Line Surge Immunity
EC Declaration of
Conformity – Low
Voltage
Compliance was demonstrated to the following specification as
listed in the Official Journal of the European Communities:
Low Voltage Directive 73/23/EEC, amended by 93/68/EEC.
HD401 S1 Safety Requirements for Electronic
Measuring Aparatus.