14.7 Changing Between Float Charge and Equalize Charge
The procedure to change the recharge mode between oat charge and equalize charge is shown in
Steps 1-3.
See the Note below for an explanation of Float and Equalize charge modes.
STEP 1
Make sure that the FLOAT CHARGE LED
is “ON”.
STEP 2
Press FLOAT/EQUAL button for at least
0.5 sec.
Change completed.
EQUAL CHARGE LED is “ON”.
FLOAT CHARGE LED is “OFF”
STEP 3
Please wait until procedure is completed.
NOTE
In equalize charge mode, the battery
is charged for a programmed period at
a specied voltage (depending on the
battery spec), rather than the oat charge,
in order to prevent voltage deviations
among battery cells. This should be done
once every six months if possible.
The G8000 UPS will automatically perform
the equalize recharge after battery backup
operation.