Toshiba G8000 Power Supply User Manual


 
61
G8000 Series Installation and Operation Manual
14.7 Changing Between Float Charge and Equalize Charge
The procedure to change the recharge mode between oat charge and equalize charge is shown in
Steps 1-3.
See the Note below for an explanation of Flaot and Equalize charge modes.
STEP 1
Make sure that the FLOAT CHARGE LED
is “ON”.
STEP 2
Press FLOAT/EQUAL button for at least
0.5 sec.
Change completed.
EQUAL CHARGE LED is “ON”.
FLOAT CHARGE LED is “OFF”
STEP 3
Please wait until procedure is completed.
NOTE
In equalize charge mode, the battery
is charged for a programmed period at
a specied voltage (depending on the
battery spec), rather than the oat charge,
in order to prevent voltage deviations
among battery cells. This should be done
once every six months if possible.
The G8000 UPS will automatically perform
the equalize recharge after battery backup
operation.
CONVERTER
INVERTER
UPS
AC OUTPUT
BATTERIES
BYPASS INPUT
DISCHARGE
EQUAL CHARGE
FLOAT CHARGE
BYPASS
AC INPUT
AC
SWITCH
UPS SUPPLY
AC - Vo 480 V
AC - Io 50%
CONVERTER
INVERTER
UPS
AC OUTPUT
BATTERIES
BYPASS INPUT
DISCHARGE
EQUAL CHARGE
FLOAT CHARGE
BYPASS
AC INPUT
AC
SWITCH
UPS SUPPLY
AC - Vo 480 V
AC - Io 50%
LED Key
- LED Off
- LED On
- LED Flash