Test Program for Field.
3.18 Log Utilities
This function logs error information generated while a test is in progress and stores the
results in RAM (Maximum error log : 500 times). This function can store data on a floppy
disk. If the power switch is turned off, the error information will be lost. Error information is
displayed in the following order:
1. Error count (CNT)
2. Test name and subtest number (TEST)
3. Pass count (PASS)
4. Error status (STS)
5. FDD/HDD or memory address (ADDR)
6. Write data (WD)
7. Read data (RD)
8. Error Name ( ERROR NAME/DETAILS)
3.18.1 Operations
1. Select 04 and press Enter in the Diagnostics Menu to log error inform
ation into
RAM or onto a floppy disk. Error information is displayed in the following format:
XXXX ERRORS
PASSCOUNT = XXXX
CNT TEST PASS STS ADDR WD RD ERROR NAME/DETAILS
001 FDD 02 0000 180 0000001 00 00 WRITE PROTECTED
002 FDD 01 0000 120 0000001 00 00 TIME OUT ERROR
Address
Error Status
Pass Count
Subtest Number Read Data
Test Name Write Data
Error Count Error Name and Detail
[[1:Next, 2:Prev, 3:Exit, 4;Clear, 5:FD Log Read, 6:FD Log Write, 7:Log Save]]
Satellite L600/L640/L645, Satellite Pro L600/Pro L640/Pro L645 Maintenance Manual (960-Q08)