Toshiba L640 Personal Computer User Manual


 
Chapter 2 Troubleshooting Procedures
Procedure 4 Diagnostic Test Program Execution Check
SD
.
escribed in Table 2-5-1. If an error code is not displayed
but the problem still occurs, go to Procedure 5.
Status
The HDD/SSD test program is stored in the Diagnostics Disk. Perform all of the HDD/S
tests in the Hard Disk Drive Test. Refer to Chapter 3, Tests and Diagnostics, for more
information about the HDD/SSD test program.
If an error is detected during the HDD/SSD test, an error code and status will be displayed
The error codes and statuses are d
Code
01 Bad Command Error
02 Bad Address Mark Error
04 Record Not Found
05 HDC Not Reset Error
07 Drive Not Initialized
09 DMA Boundary Error
0A Bad Sector
0B Bad Track Error
10 ECC Error
11 ECC Recover Enabled
20 HDC Error
40 Seek Error
80 Time Out Error
AA Drive Not Ready
Table 2-5-1 HDD/SSD error code & status
BB Undefined Error
CC Write Fault
E0 Status Error
F0 No Sense Error
?? Other Error
Satellite L600/L640/L645, Satellite Pro L600/Pro L640/Pro L645 Maintenance Manual (960-Q08)
