2 Troubleshooting Procedures
Satellite A350D/A355D, SATEGO A350D, EQUIUM A350D Series Maintenance Manual
10
2.3 Power Supply Troubleshooting
START
Are the DC-IN and
Battery LEDs lit?
Can you turn the
computer on?
Are the internal power
connections secure?
END
Check Power Supply Status
(Procedure 1)
No
Yes
Check power supply
connections
(Procedure 3)
Run diagnostic program
(Procedure 4)
Yes
No
Replace adaptor / battery
(Procedure 2)
No
Perform internal connection
check
(Procedure 5)
Replace system board
Yes