Toshiba TDP-P7 Projector User Manual


 
E-54
When an Indicator is Lit or Flashing
STANDBY
STATUS
MENU
QUICK
MENU
S
O
U
R
C
E
A
U
T
O
STATUS STANDBY
STATUS STANDBY
STANDBYSTATUS
STANDBYSTATUS
STANDBYSTATUS
The indicators on the projector’s control panel light or flash to
notify of problems, as described below.
An indicator is also used to notify you of the currently set power
mode. See “Power Cable Connections and Switching the Power
On/Off” on page E-19.
Indicator status What you should do
When the power is on (Lit green)
Standby (Lit amber)
Lit red
Flashing amber for 60 seconds, then lit
amber
Lit red
Lit red
Flashing red
(lit for 1 seconds/off for 1 seconds)
Lit red
Flashing red
(lit for 0.5 seconds/off for 0.5 seconds)
Lit amber
Flashing red
(lit for 0.5 seconds/off for 0.5 seconds)
When the lamp has burned out dur-
ing use
Flashing amber for 90 seconds, then lit
amber
When the lamp does not come on
from the start
Lit amber
Flashing red
(lit for 1 seconds/off for 1 seconds)
It is time to replace the lamp.
Replace with a new lamp cartridge.
The lamp has reached the end of its service life. The power
will no longer turn on.
The projector can be used for 100 hours after the lamp has reached
the end of its service life.
Replace with a new lamp cartridge.
The lamp cover is open.
The lamp cover is not properly mounted. Mount it properly.
The temperature is abnormally high.
The temperature protector has been activated. If the room tem-
perature is high, move the projector to a cool place. If the
projector’s internal temperature is high, check the cooling fan’s
ventilation slots and clean them if they are clogged.
When the temperature protector is activated, the power turns
off and in some cases will not turn back on immediately. In this
case wait about 90 seconds, then try again.
The fan has stopped.
Unplug the power cable and contact a store that sells the TDP-P7
for repairs.
The lamp will not light.
Wait at least 90 seconds, then turn the power back on. If the prob-
lem persists, unplug the power cord and contact a store that sells
the TDP-P7 for repairs.
STANDBYSTATUS
Should an indicator be in a condition other than normal or flash at a rate other than the aforementioned, disconnect the power
cable and contact your store of purchase.
Thermal Protector
When the temperature inside the projector becomes abnormally high, the STATUS indicator flashes red (0.5 seconds on/0.5
seconds off), the STANDBY indicator is a steady red, and at the same time the temperature protector operates and switches off
the power of the projector.
Should this happen, please take the following actions.
1. Switch off the power and disconnect the power plug from the wall outlet.
2. Check the following matters and take the required measures.
When the projector is being used in a location that has a high ambient temperature, set it up again in a cool location. Check the
outflow and intake holes and clean them if they are obstructed.
3. Wait about 60 minutes until the temperature of the projector drops.
If after having performed the above matters, the problem still has not been solved, please contact your store of purchase.
STANDBY indicator
STATUS indicator