TP-Link TL-SG2452 Switch User Manual


 
be sent out (the number of LLDPDUs equals this parameter). The value ranges
from 1 to 10 and the default value is 3.
Command Mode
Global Configuration Mode
Example
Specify the Transmit Interval of LLDPDU as 45 seconds and Trap message to
NMS as 120 seconds:
TL-SG2424P(config)# lldp timer tx-interval 45
TL-SG2424P(config)# lldp timer notify-interval 120
lldp med-fast-count
Description
The lldp med-fast-count command is used to configure the number of the
LLDP-MED frames that will be sent out. When LLDP-MED fast start mechanism
is activated, multiple LLDP-MED frames will be transmitted based on this
parameter. The default value is 4. To return to the default configuration, please
use no lldp med-fast-count command.
Syntax
lldp med-fast-count count
no lldp med-fast-count
Parameter
count —— Configure the Fast Start Count parameter. It ranges from 1 to 10. By
default, it is 4.
Command Mode
Global Configuration Mode
Example
Specify Fast Start Count as 5:
TL-SG2424P(config)# lldp med-fast-count 5
lldp receive
Description
The lldp receive command is used to enable the designated port to receive
LLDPDU. To disable the function, please use no lldp receive command.
207