Transition Networks CPSMC0810-100 Switch User Manual


 
11
CPSMC08xx-100 PointSystem
Chassis
slide-in-modules
2.2.3 Replacing the Management Modules
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when replacing media converter slide-in-module(s). Failure to observe
this caution could result in damage to, and subsequent failure of, the management
module(s).
NOTE: The management modules can be replaced while the chassis remains
powered. However, you must configure a new IP address for the replacement
management module. For more information, see the FocalPoint™ 2.0 user’s guide
on the enclosed application CD or on-line at www.transition.com.
To replace a management module in the CPSMC08xx-100 chassis:
1. Remove the management module to be replaced by loosening the panel
fastener screw that secures the module to the chassis front. Slide the module
from the chassis.
2. Align the replacement module with the installation slot so that the panel
fastener screw to the left of the module..
3. Carefully slide the replacement management module into the installation slot,
while aligning the module’s circuit board with the installation guides.
NOTE: Ensure that the management module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the
management module to the chassis.
24 hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
PWR
CPSMC-0800
8-Slot Chassis
Mpls, MN 55344
Mpls, MN 55344
Input Power:
Input Power:
110-240 VAC
110-240 VAC
1.6A max. (60W max)
1.6A max. (60W max)
50/60 Hz
50/60 Hz
RX
TX
LNK
PWR
RESET
DB-9
Panel Fastener Screw