Transition Networks SIBTF10XX-1XX-MS Switch User Manual


 
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
21
Cable Specifications -- continued
SIBTF1013-1xx-Mx 1300 nm multimode
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget: 11.0 dB
SIBTF1014-1xx-Mx 1310 nm single mode
Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm
Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm
Link Budget: 16.0 dB
SIBTF1015-1xx-Mx 1310 nm single mode
Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget: 26.0 dB
SIBTF1016-1xx-Mx 1310 nm single mode
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget: 29.0 dB
SIBTF1017-1xx-Mx 1550 nm single mode
Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm
Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm
Link Budget: 29.0 dB
This device is certified by the manufacturer to comply with DHHS Rule
21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare
into beam or view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures
other than those specified herein may result in hazardous radiation exposure.
The fiber optic transmitters on this device meet Class I Laser safety
requirements per IEC-825/CDRH standards and comply with 21
CFR1040.10 and 21CFR1040.11.
20
SIBTF10xx-1xx-Mx
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Copper Cable
Category 3: (Minimum requirement for 10 Mb/s operation)
Gauge 24 to 22 AWG
Attenuation 11.5 dB/100m @ 5-10 MHz
Maximum Cable Distance 100 meters
Category 5: (Minimum requirement for 100 Mb/s operation)
Gauge 24 to 22 AWG
Attenuation 22.0 dB/100m @ 100 MHz
Maximum Cable Distance 100 meters
• Straight-through or crossover twisted-pair cable may be used.
• Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Fiber cable
Bit Error Rate: <10-9
single mode fiber (recommended): 9 μm
Multimode fiber (recommended): 62.5/125 μm
Multimode fiber (optional): 100/140, 85/140, 50/125 μm
SIBTF1011-1xx-Mx 1300 nm multimode
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Link Budget: 11.0 dB
Straight-Through Cable
Twisted Pair #1
Twisted Pair #2
1
2
3
6
1
2
3
6
Crossover Cable
Twisted Pair #1
Twisted Pair #2
1
2
3
6
1
2
3
6
Figure 16: Copper Cable Configurations
WARNING: Visible and invisible laser radiation when open. Do not stare
into the beam or view the beam directly or with optical instruments. Failure
to observe this warning could result in an eye injury or blindness.
WARNING:
Use of controls, adjustments, or the performance of
procedures other than those specified herein may result in hazardous
radiation exposure.