Transition Networks SIBTF10XX-1XX-MS Switch User Manual


 
24
SIBTF10xx-1xx-Mx
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Standard Description Compliance Level Remarks
IEEE1613, Power Substation Testing -- Continued
IEEE1613, Clause 7.3.2 Class 2 transverse mode
Class 1 common mode
Surge fast transient
waveform – power AC
Class 2 transverse mode
Class 1 common mode
Surge fast transient
waveform – power DC
Class 1 common mode Surge fast transient
waveform – relay port
Class 1 common mode Surge fast transient
waveform – Ethernet 10
Mbps
Class 1 common mode Surge fast transient
waveform – Ethernet 100
Mbps
IEEE1613, Clause 8 Class 2 Radio frequency
susceptibility
IEEE1613, Clause 9 Class 1 ESD contact discharge 8kV
EMC Type Tests -- Continued
Technical Specification -- continued
Troubleshooting
If the industrial switch fails, isolate and correct the failure by determining the answers
to the following questions and then taking the indicated action:
1. Is the “PRI” (primary power) LED illuminated?
NO
Ensure the power source is the proper voltage (48–170 VDC or 90–125
VAC, 50/60Hz).
Ensure that the positive, negative, and ground wires from the power
source are properly connected to the primary inputs.
Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
Proceed to step 2.
2. (SIBTF10xx10x-MR models only) is the “AUX” (auxiliary power) LED
illuminated?
NO
If the device does not have an auxiliary power source, proceed to step 3.
Ensure the power source is the proper voltage (48–170 VDC or 90–125
VAC, 50/60Hz).
Ensure that the positive, negative, and ground wires from the power
source are properly connected to the auxiliary inputs.
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
YES
Proceed to step 3.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
25
Troubleshooting -- continued
3. Is the “FAULT” LED illuminated?
NO
Proceed to step 4.
YES
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600.
4. For each port with a cable installed is either the “10MB” or the “100MB” LED
illuminated?
YES
Proceed to step 5.
NO
For each port with a cable installed and its LED is OFF, check the cable
for proper connection.
For the fiber ports, verify that the TX and RX cables on the SIBTF10xx-
10x are connected to the RX and TX ports, respectively, on the device at
the other end of the fiber cables.
Contact Technical Support: US/Canada: 1-800-260-1312, International:
00-1-952-941-7600
5. For each RJ-45 port with a cable installed (ports 1, 2, 3, and 4), check to see if
the 10MB or 100MB LED is illuminated.
10MB is ON = The industrial switch has selected 10Mb/s operation.
100MB is ON = The industrial switch has selected 100Mb/s operation.
If the speed is not correct, disconnect and reconnect the cable to restart the
initialization process.
Proceed to step 6.
6. For each fiber port with a cable installed, is the “FD” (full-duplex) LED
illuminated?
NO
The industrial switch has selected half-duplex mode.
If the mode is not correct, disconnect and reconnect cable to restart the
initialization process.
Check the cable for proper connection.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
The industrial switch has selected full-duplex mode.
If the mode is not correct, disconnect and reconnect cable to restart the
initialization process.
Check the cable for proper connection.
Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.