Tripp Lite B020-008-17-IP Switch User Manual


 
B020-008-17-IP User Manual
58
ANMS
The Advanced Network Management Settings dialog box allows you to set up
login authorization management from a external sources. It is divided into two
main panels, as described, below:
RADIUS Settings
To allow authorization for the B020-008-17-IP through a RADIUS server, do
the following:
1. Check Enable Radius.
2. Fill in the IP addresses and Service Ports for the Primary and Alternate
RADIUS servers.
3. Set the time in seconds that the B020-008-17-IP waits for a RADIUS
server reply before it times out in the Timeout field.
4. Set the number of RADIUS retries allowed in the Retries field.
5. Key the Shared Secret character string that you want to use for
authentication between the B020-008-17-IP and the RADIUS Server in
this field.
Note: Set the access rights for each user on the RADIUS server according to
the information in the table on the next page.