Tripp Lite B072-016-1 Switch User Manual


 
13
Operation
(continued)
Time Settings
In the Settings window navigate to the Time line and press [Enter]. The Time settings
window appears )see Figure 13).
Figure 13 Time settings window
Scan (SCN) - Label (LBL) - Time out (T/O)
SCN - Sets the scan period.
LBL - Sets the amount of time the OSD label that show which computer is currently
accessed is displayed.
T/O - When password protection is activated, you can automatically disable the keyboard,
mouse and screen after a set amount of idle time.
To set the above periods:
1. On the desired line press Tab to jump to the desired column.
2. Place the cursor over one of the 3 digits and type a new number. Enter a leading zero
where necessary. For example, type 030 for 30 seconds.
Enter 999 in the LBL column to have the label displayed continuously. Enter 000 if you
do not want the label to appear.
Enter 999 in the T/O column to disable the Timeout function.
Enter 000 if you want the Timeout function to work immediately. (WARNING: we
suggest a minimum time of no less than 005 seconds as 000 causes the timeout function
to work immediately.)
Enter 999 in the SCN column to display the screen for 999 seconds.
Enter 000 to skip the computer screen.
Users
In the Settings window navigate to the Users line and press [Enter]. The Users settings
window appears (see Figure 14).
Figure 14 The Users Settings Window
200512060 93-2520 B072 series OM.qxd 3/6/2006 11:17 AM Page 13