Tripp Lite SMX1500LCD Power Supply User Manual


 
Owner’s Manual
SMX1500LCD Digital UPS System
Not suitable for mobile applications.
1111 W. 35th Street • Chicago, IL 60609 USA • +1 773 869 1234 • www.tripplite.com
Copyright © 2007 Tripp Lite. All rights reserved.
Español Français
Póññêèé
5
9
13
Important Safety Instructions
SAVE THESE INSTRUCTIONS
The manual contains instructions and warnings that should be followed during the installation, operation and storage of this product. Failure
to heed these warnings will void your warranty.
UPS Location Warnings
The UPS is designed for indoor use only in a controlled
environment, away from excess moisture, temperature extremes,
conductive contaminants, dust or direct sunlight.
Leave adequate space around all sides of the UPS for proper
ventilation.
Do not mount unit with its front or rear panel facing down (at
any angle). Mounting in this manner will seriously inhibit the
unit's internal cooling, eventually causing product damage not
covered under warranty.
UPS Connection Warnings
• Connect the UPS directly to a properly grounded AC power outlet.
Do not plug the UPS into itself; this will damage the UPS.
• Do not modify the plug of the UPS, and do not use an adapter that
eliminates the ground connection of the UPS.
• Do not use extension cords to connect the UPS to an AC outlet.
The warranty will be void if anything other than Tripp Lite surge
suppressors are used to connect the UPS to an outlet.
• If the UPS receives power from a motor-driven AC generator, the
generator must provide clean, filtered, computer-grade output.
Equipment Connection Warnings
• Do not use Tripp Lite UPS Systems for life support applications in
which a malfunction or failure of a Tripp Lite UPS System could cause
failure or significantly alter the performance of a life support device.
• Do not connect surge suppressors or extension cords to the output
of the UPS. This might damage the UPS and will void the surge
suppressor and UPS warranties.
Battery Warnings
• The UPS does not require routine maintenance. Do not open the
UPS for any reason. There are no user-serviceable parts inside.
• Batteries can present a risk of electrical shock and burns from high
short-circuit current. Observe proper precautions. Do not dispose
of the batteries in a fire. Do not open the UPS or batteries. Do not
short or bridge the battery terminals with any object. Unplug and
turn off the UPS before performing battery replacement. Use tools
with insulated handles. Battery replacement should be performed
only by authorized service personnel using the same number and
type of batteries (sealed Lead-Acid). The batteries are recyclable.
Refer to your local codes for disposal requirements. Tripp Lite
offers a complete line of replacement batteries at
www.tripplite.com.
• Do not attempt to add external batteries to the UPS.