ViewSonic VS11334 Projector User Manual


 
Maintenance
Air filter (continued)
5.
Apply a vacuum cleaner to the air filter and filter cover.
Then set a new or cleaned air filter into place.
In case of the filter cover for bottom-up use, remove the air filter from the filter
cover and clean each. After cleaning, reattach the cleaned filter to the filter cover.
Please replace the air filter when it is damaged or too soiled.
6.
Position the air filter and filter cover into place.
7.
Slowly turn the projector so that the top is facing up, except for the case of
bottom-up use.
8.
Turn the projector on and reset the filter time using the FILTER TIME function
in the OPTION menu.
(1) Press the MENU button to display a menu. When the EASY MENU has ap
-
peared, please skip the next step (2).
(2) Point at the “OPTION” in the left column of the menu using ▼/▲ button, then
press the ► button.
(3) Point at the “FILTER TIME” using ▼/▲ button, then press the ► button. A
dialog will appear.
(4) Press the ▲ button to select “RESET” on the dialog. It performs resetting the
filter time.
Claws
Air filter
Rail of air filter
Filter cover for bottom-up use
Usual filter cover
Push the points of “PUSH” word
with claws to fix the air filter.
Interlocking the tabs,
snap the filter cover into place.
Filter cover for bottom-up use
Interlocking the tabs, snap the filter cover into place.
Tabs
Tabs
45ViewSonic PJ452