Western Digital Studio Edition II Computer Drive User Manual


 
MY BOOK STUDIO EDITION II
USER MANUAL
WD RAID MANAGER FOR MAC – 21
Disk Status Messages
WD RAID Manager reports the following messages depending on the current status
of your Disk A and B.
Displayed Status
Text
Description User Action
Good The slot configuration
contains valid data.
Consult the array status
to see if other errors have
been detected.
None
No hard disk The slot contains no HDD Install drive in empty slot.
No Config The slot does not contain
a valid configuration.
Create New RAID set. (Loss of
data)
Mismatched capacity. Replace
drive with identical capacity
drive and re-create RAID set.
Faulty The slot is marked as
faulty.
Replace drive.
Rebuilding The slot is currently being
rebuilt from the other slot.
Wait for rebuild to complete.
This will take several hours.
Good Initialization failed to
complete.
Replace other drive.
Rejected The slot contains an HDD
that does not meet the
unit’s requirements.
Install drive that is compatible
with RAID device.
Only WD Green Drives are
compatible.