Western Telematic MPC-20VS20-1 Network Card User Manual


 
9-6
Operation
When switching and reboot commands are executed, the MPC will display a "Sure?"
prompt, wait for user response, and then complete the command. The unit will pause
for a moment while the command is executed, and then return to the Plug Status
Screen. To Switch Plugs, or initiate a Reboot Cycle, proceed as follows:
1. Switch Plug(s) On:
a) Local MPC Units or Individual MPC Units: To power-on a plug or Plug
Group, type /ON n and press [Enter]. Where "n" is the alphanumeric number
or name of the desired plug or Plug Group. For example:
/ON A1 [Enter] or /ON ROUTER [Enter]
b) AUX/Remote MPC Units: If your local MPC unit is connected to one or more
optional AUX/Remote MPC units, type /ON aux n and press [Enter]. Where
"aux" is the AUX/Remote unit and "n" is the alphanumeric number or name of
the desired plug. For Example, to switch On Plug A1 on the AUX1 unit, enter
the following:
/ON AUX1 A1 [Enter]
Note: Enter a space to separate the AUX parameter from the Plug number.
2. Switch Plug(s) Off:
a) Local MPC Units or Individual MPC Units: To power-off a plug or Plug
Group, type /OFF n and press [Enter]. Where "n" is the alphanumeric number
or name of the desired plug or Plug Group. Note that the “/OFF” command
can also be entered as “/OF”. For example:
/OFF B2 [Enter] or /OF ROUTER [Enter]
b) AUX/Remote MPC Units: If your local MPC unit is connected to one or more
optional AUX/Remote MPC units, type /OFF aux n and press [Enter]. Where
"aux" is the AUX/Remote unit and "n" is the alphanumeric number or name
of the desired plug. Note that the “/OFF” command can also be entered as
/OF”. For Example, to switch Off Plug A2 on the AUX3 unit, enter either of the
following command lines:
/OFF AUX3 A2 [Enter] or /OF AUX3 A2 [Enter]
Note: Enter a space to separate the AUX parameter from the Plug number.