Xantech DCH4 Switch User Manual


 
08905107C - 4 -
B. Quick Programming Features
Enter Digits - then -
Memory
Location
Privacy Number (factory disabled) 0-6 digits (0-9) + #00
Entry phone 1 keyless entry codes (factory disabled) 4-6 digits (0-9) + #11 - #16
* Entry phone 1 one time use keyless entry codes (factory disabled) 4-6 digits (0-9) + *#11 - *#16
Entry phone 2 keyless entry codes (factory disabled) 4-6 digits (0-9) + #21 - #26
* Entry phone 2 one time use keyless entry codes (factory disabled) 4-6 digits (0-9) + *#21 - *#26
Entry phone 3 keyless entry codes (factory disabled) 4-6 digits (0-9) + #31 - #36
* Entry phone 3 one time use keyless entry codes (factory disabled) 4-6 digits (0-9) + *#31 - *#36
Entry phone 4 keyless entry codes (factory disabled) 4-6 digits (0-9) + #41 - #46
* Entry phone 4 one time use keyless entry codes (factory disabled) 4-6 digits (0-9) + *#41 - *#46
Master keyless entry codes (factory disabled) 4-6 digits (0-9) + #51 - #56
* Master one time use keyless entry codes (factory disabled) 4-6 digits (0-9) + *#51 - *#56
Doorstrike 1 activation time (.5 - 99 secs, factory set to 00 = .5 secs) 2 digits (00-99) + #19
Doorstrike 2 activation time (.5 - 99 secs, factory set to 00 = .5 secs) 2 digits (00-99) + #29
Doorstrike 3 activation time (.5 - 99 secs, factory set to 00 = .5 secs) 2 digits (00-99) + #39
Doorstrike 4 activation time (.5 - 99 secs, factory set to 00 = .5 secs) 2 digits (00-99) + #49
** Auxiliary Contacts:
Auxiliary contact timing (.5 - 99 secs, factory set to 00 = .5 secs, DIP
switch 1 off)
2 digits (00-99) + #59
1. Entry phone triggered timed activation (factory setting, DIP switch 1
off)
1 + #60
2. Entry phone triggered continuous activation 2 + #60
3. Entry phone triggered ring cadence activation 3 + #60
4. Auxiliary input triggered timed activation 4 + #60
Maximum entry phone ring count (1 - 99 rings, factory set to 5 rings) 2 digits (01-99) + #61
Enable entry phone ringing (factory setting) 1 + #62
*** Disable entry phone ringing 0 + #62
Security code (factory set 845464) 6 digits (0-9) + #47
Enable entry phone Caller ID (factory setting) *1
Disable entry phone Caller ID *2
Entry phone calls give custom double ring cadence (factory setting) *3
Entry phone calls give standard ring cadence *4
Dial “9” to access an outside line *5
Instant outside line access (factory setting, for use with private dial
tone)
*6
Enable doorstrike latching commands (factory setting) *7
Disable doorstrike latching commands *8
Enable entry phone identifier beeps (factory setting) *9
Disable entry phone identifier beeps *0
Reset all programming to factory default settings ###
* Note: A keyless entry code can be programmed for EITHER an unlimited number of uses or one
time use, NOT both. There can be a maximum of 6 keyless entry codes and/or one time use keyless
entry codes per entrance.
** Note: Auxiliary contact programming is only to be used if the DCH4 is in the Auxiliary Contact
Mode (DIP switch 1 OFF), see DIP Switch Programming section D.
*** Note: Only entry phone call waiting Caller ID will function in this mode, standard entry phone
Caller ID will not.