C. Security Code
This six digit number can be used to access the programming mode. The security code has been
factory set to 845464. It is recommended that you change the security code to a personal 6 digit
number. To change the security code, access programming (see Programming section A). Enter six
digits 0-9 followed by #47. If you have forgotten your security code, follow the steps in Programming
section A, 2. Accessing the Programming Mode Locally (Security Code Bypass Mode). Note:
The security code must be six digits in length and can NOT contain a * or #.
D. DIP Switch Programming
SWITCH POSITION DESCRIPTION
1 OFF Auxiliary Contact Mode.
1 ON Doorbell Mode (Factory setting).
2 OFF Normal Operation Mode (Factory setting).
2 ON Security Code Bypass Mode.
3 OFF Entry Phone automatic disconnect (CPC) disabled.
3 ON
Entry Phone automatic disconnect (CPC) enabled
(Factory setting).
4 OFF Entry Phone busy signal disabled.
4 ON Entry Phone busy signal enabled (Factory setting).
E. Privacy Number
The “Privacy Number” is factory disabled so an entry phone off-hook will automatically ring the house
phones. If a “Privacy Number” is programmed, the visitor must Touch Tone dial the number to be able
to call into the house. The “Privacy Number” may be from 1 to 6 digits and is stored in location “#00”.
To disable the “Privacy Number,” clear the number’s memory location by entering “#00” without any
previous digits.
F. Keyless Entry Codes and One Time Use Keyless Entry Codes
Each entry phone may have a combination of up to 6 keyless entry codes or one time use keyless
entry codes for Touch Tone keyless entry. The keyless entry codes may be from 4 to 6 digits in length
and are stored in locations #11 - #16 for entry phone 1, #21 - #26 for entry phone 2, #31 - #36 for
entry phone 3, and #41 - #46 for entry phone 4. Up to 6 master keyless entry codes may be from 4 to
6 digits in length and are stored in locations #51 - #56. The master keyless entry codes can be used
at any entry phone. To change any of the keyless entry codes to one time use, insert a * in front of
the specific memory location during programming (ie: “*#11”). To clear any keyless entry codes,
simply enter the location number (ie: “#11” or “*#11”) without any previous digits.