Table 1.1 Specifications for XT 60 W Series Supply with RS-232 Interface Installed
Models 7-6 15-4 20-3 30-2 60-1 120-0.5 250-0.25
Program Resolution
Voltage
Current
OVP
1.1mV
1.0mA
1.0mV
2.4mV
0.6mA
2.4mV
3.1mV
0.5mA
3.1mV
4.7mV
0.3mA
4.7mV
9.3mV
0.2mA
9.3mV
17mV
0.1mA
17mV
34mV
0.08mA
34mV
Program Accuracy
1
Voltage
Current
OVP
1. Apply accuracy specifications according to the following voltage program accuracy example:
Set a model XT 15-4 power supply to 10 volts.
The expected result will be within the range of 10 volts ± 20mV ± 0.1% of the set voltage of 10 volts.
10mV
±0.1%
110mA
±0.15%
70mV
20mV
±0.1%
70mA
±0.15%
150mV
20mV
±0.15%
50mA
±0.15%
200mV
30mV
±0.15%
40mA
±0.15%
300mV
200mV
±0.15%
26mA
±0.2%
600mV
400mV
±0.15%
13mA
±0.2%
1.2V
800mV
±0.15%
7mA
±0.2%
2.4V
Readback Resolution
Voltage
Current
1.1mV
1.0mA
2.4mV
0.6mA
3.1mV
0.5mA
4.7mV
0.3mA
9.3mV
0.2mA
17mV
0.1mA
34mV
0.08mA
Readback Accuracy
1
Voltage
Current
10mV
±0.15%
110mA
±0.15%
10mV
±0.1%
70mA
±0.15%
10mV
±0.1%
50mA
±0.15%
15mV
±0.1%
40mA
±0.15%
35mV
±0.15%
26mA
±0.2%
70mV
±0.15%
13mA
±0.2%
140mV
±0.15%
7mA
±0.2%