Xantrex Technology XDC 20-300SL Power Supply User Manual


 
Specifications and Characteristics
Output Performance Specifications
28 Operating Manual for XDC Series Slave Power Supply
Typical Programming Resolution
Typical Measurement Resolution
Programming Accuracy
1
Readback Accuracy
30 Minute Drift
2
Remote Digital Interface
Voltage
Current
Power
Over Voltage Protection
0.002% of Vmax
0.002% of Imax
0.05% of Pmax
0.002% of Vmax
Remote Digital Interface
Voltage
Current
Power
0.002% of Vmax
0.002% of Imax
0.05% of Pmax
Remote Digital Interface
Voltage Programming
Current Programming
Power Programming
Over voltage
Programming
0.1% of Vmax
0.5% of Imax
0.5% of Pmax
0.1% of Vmax
1. Accuracy specifications apply for settings in range of 1% to 100% of rated output
Remote Digital Interface
Voltage Readback
Current Readback
Power Readback
0.15% of Vmax
0.5% of Imax
0.5% of Pmax
Voltage 0.04% of Vmax
Current 0.6% of Imax
Power 1% of Pmax
2. At 25°C ±5°C, with full power load
TM-XDSL-01XN.book Page 28 Tuesday, November 5, 2002 3:22 PM