Xantrex Technology XDC 20-300SL Power Supply User Manual


 
Specifications and Characteristics
Output Performance Specifications
Release 1.0 29
8 Hour Drift Temperature Stability
1
Temperature Coefficients
Switching Frequency
Typical 31 kHz; 62 kHz output ripple
Rise Time
5 to 95% step in output voltage.
Fall Time
For a programmed 95% to 5% step in output voltage.
Time Delay From Power On Until Output Stable
5 s maximum
(Within regulation envelope)
Voltage 0.02% of Vmax
Current 0.04% of Imax
Power 0.1% of Pmax
1. At 25°C ±5°C after 30 minutes full load operation
Remote Digital Interface
Voltage Programming
Current Programming
Power Programming
Voltage Readback
Current Readback
Power Readback
0.04% of Vmax
/°C
0.06% of Imax/°C
0.1% of Pmax/°C
0.04% of Vmax/°C
0.06% of Imax/°C
0.1% of Pmax/°C
Load Condition Time (Max)
No Load 100 ms
Full Load 100 ms
Load Condition Time (Max)
No Load
1
1. Fall time is 4s for 300 V and 600 V units.
3s
Full Load 50 ms