4.2 Environmental Information
Dimensions
170 x 185 x 27 mm
Unit Weight
637g
Power
DC 5V/2A
Operating Temperature
0°C to 50°C (32°F to 122°F)
Storage Temperature
-40°C to 70°C (-40°F to 158°F)
Operating Humidity
20% to 95% relative humidity, non-condensing
Storage Humidity
20% to 95% relative humidity, non-condensing
4.3 Standard Conformance
EMC Certification
FCC Class B, CE
4.4 Cable Specifications
Ethernet Type Cable Requirements Maximum Length
10BASE-T
Category 3 or better, UTP or STP 328 ft (100M)
100BASE-TX
Category 5 or better, UTP or STP 328 ft (100M)
1000BASE-T
Category 5e or better, UTP or STP 328 ft (100M)
Caution: Please do not use telephone cables. Telephone cables do not support
Ethernet or Fast Ethernet
There are two types of cables: Straight Through Cables and Crossover Cables.
Category 5 UTP/STP cable has eight wires inside the sheath. The wires form four pairs.
Straight Through Cables has same pin-outs at both ends while Crossover Cables has a
different pin arrangement at each end.
Figure 4-1 shows the diagram of Straight Through Cables. Figure 4-2 shows the