Zebra Technologies XiIIIPlus Printer User Manual


 
O-12
UMAN-CM2/3
Cleaning the Media Sensor
The Media sensor is located inside the media compart-
ment under the print head. Blow out any dust deposits
carefully, then finish cleaning with the cleaning pen sup-
plied with the printer and/or alcohol and cotton swabs.
The Cameo 2
plus
has a Sensor Assembly that is
mounted external to the printer mechanism. (Refer to
detail on the previous page). The same cleaning proce-
dure should be followed for this sensor, paying particular
attention to cleaning dust from within the gap the media
passes through.
Linerless Media Printers
Printers using linerless media require more frequent
cleaning. Linerless media deposits adhesive which must
be removed for optimum performance. Linerless printers
can be identified by a platen which is
not
black, or by
reading the unit’s fifteen digit Product Configuration
Code (PCC) label on the back of the printer. PCC digit
“8” will be “B”, “”D”, “F”, or “H” for linerless printers.
Note: It is not necessary to clean the platen on linerless
units. The platen material is self cleaning and will not
require constant maintenance.
When cleaning, use only the Cleaning Pen provided with
each printer or isopropyl alcohol.
•Open the printer by squeezing the finger grips on
either side of the media compartment cover.
•Surfaces inside the media compartment that come
in contact with the linerless media adhesive should
be cleaned, along with:
Print mechanism area around the Sensor
•Printhead
•Inside surface of the edge guide
Allow printer to dry before resuming printing.