CONTROLS
Keypad Functions
On Switch:
momentary action
turns on unit
IR Window;
must be aligned with
corresponding window on host
for IR communications to occur.
(Units with IR option only)
Feed Switch:
Advances media
when held down.
Status Light: Steady
light indicates printer is
either out of media, or
media cover is open.
Flashing during data
transmission between
host and printer
indicates normal
wireless operation.
Power Light:
Indicates unit
is turned on
Flashing light
indicates low
battery
Self Test
Cameos can perform a self test which will print a line of
interlocking “x” characters to insure all elements of the
print head are working, and then print out the version of
software loaded in the printer. Refer to the Troubleshoot-
ing section for details on interpreting the self-test.
The self test is activated by the following key
sequence:
1.Press the "FEED" key
2.While still holding down the "FEED" key, turn on
the printer by pressing and releasing the "ON" key.
3.Keep the "FEED" key depressed until self test
starts.
The Cameo will perform the self test and remain on.