Zhone Technologies 4821-A2 Modem User Manual


 
Installation
14 BitStorm 4800 Express Model 4821-A2 Installation Guide 4821-A2-ZN21-30
Preparation
Consider the following before installing the BitStorm 4800 Express IP
DSLAM:
z Installation Site
Your installation site should be well ventilated, clean, and free of
environmental extremes.
z Installation Options
The BitStorm 4800 Express may be:
Mounted with the included mounting brackets in a standard 19-inch
(483 mm) or 23-inch (584 mm) rack (including both Bay Networks
and Nortel 23-inch racks), or, with separately purchased mounting
brackets, in a 21-inch (535 mm) ETSI rack. ETSI brackets are
available from Paradyne. See Appendix B-, Equipment List.
As many BitStorm 4800 Express units may be mounted in a standard
rack as there are 1.75-inch (44.45 mm) spaces in the rack, so long as
adequate cooling is provided.
Mounted vertically against a wall.
The standard mounting brackets provided can be fastened to the base
of the unit for wall mounting.
Set on a shelf or desktop.
Up to five BitStorm 4800 Express units may be stacked on a shelf or
desktop.
z Power
The BitStorm 4800 Express operates from a 90 to 265 VAC, 47 to 63 Hz
power source.
z Cabling
No cable except the power cable is provided with the BitStorm 4800
Express. See Table 2, Cable Descriptions, to determine what cables you
need to procure before installation.