![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/68/1688fa09-80aa-4e3e-abe4-3583d150771d/1688fa09-80aa-4e3e-abe4-3583d150771d-bg30.png)
48 OES 2: NetWare Traditional File System Administration Guide
novdocx (en) 6 April 2007
Procedure
Use the “SET” command as described in the OES 2: Utilities Reference to disable the Disk Read
After Write Verification parameter.
7.4 Configuring SET Parameters for the NetWare
Traditional File System
Table 7-1 indicates the default settings in NetWare 6.5 or later for the Traditional file system SET
parameters.
Table 7-1 SET Parameters for a Traditional File System Volume
SET Parameters for the Traditional File System Default Value
Volume Log File State 1
Volume TTS Log File State 1
Volume Log File Overflow Size 4194304
Volume TTS Log File Overflow Size 4194304
Auto TTS Backout Flag On
TTS Abort Dump Flag Off
TTS UnWritten Cache Wait Time 1 minute 5.9 seconds
TTS Backout File Truncation Wait Time 59 minutes 19.2 seconds
Dirty Directory Cache Delay Time 0.5 seconds
Directory Cache Allocation Wait Time 2.2 seconds
Directory Cache Buffer NonReferenced Delay 5.5 seconds
Maximum Directory Cache Buffers 2000
Minimum Directory Cache Buffers 500
Maximum Number Of Internal Directory Handles 100
Maximum Number Of Directory Handles 20
Maximum Record Locks Per Connection 500
Maximum File Locks Per Connection 2500
Maximum Record Locks 20000
Maximum File Locks 200000
Read Ahead Enabled On
Read Ahead LRU Sitting Time Threshold 10 seconds
Minimum File Cache Buffers 20
Maximum Concurrent Disk Cache Writes 750