4-8
Criteria - There should not have any lack of RGBW. The
color should appear normal and sort in right
order.
- Color levels should be sufcient and normal.
(the unidentied color levels on both left and
right sides should not over 8 color levels.)
- Grey level should not have abnormal color or
heavy lines.
2. PC calibration
Procedure - Test equipment: video generator
- Once main board is changed, PC calibration
should be done as well.
(1) Test signal analog: 1024x768@60Hz
(2) Test Pattern: White(up) Black(down)
- Note
(1) Caibration pattern should be in ll screen
mode.
(2) Please refer to 4-2 Guide to Entering Service
Mode and OSD Reset.
(3) Choose and access PC Calibration for cor-
rection in service mode. Choose “menu” to
leave the service mode after all.
Check pattern - Test signal: analog 1024 x 768@60Hz
- Test pattern: In focus II or 64 grey RGBW
* After nishing ADC adjustment, check 64 gray
RGBW pattern.
Inspection item - Color sturations
Criteria - There should not have any lack of RGBW. The
color should appear normal and sort in right
order.
- Color levels should be sufcient and normal.
(the unidentied color levels on both left and
White / Black
In focus 2 / 64 gray
RGBW