ADC L997 Computer Monitor User Manual


 
[Procedure]
1. Select <Off Timer> in the ScreenManager <Others> menu.
2. Select "Enable" and press the Right and Left buttons to adjust the "On Period" (1 to 23 hours).
[Off Timer System]
PC
Monitor
Power Indicator
On Period (1H - 23H)
Operation
Blue
Last 15 min. in "On period"
Advance Notice
*
1
Blue Flashing
"On period" expired
Power Off
Flashing yellow slowly
*1 Advance notice (Power Indicator flashing blue) will be given 15 minutes before the monitor
automatically enters the "Power Off" mode. To delay entering the "Power Off" mode, press the Power
button during the advance notice period. The monitor will continue to operate for an additional 90
minutes.
[Power Resumption Procedure]
Press the Power button to return to a normal screen.
The off timer function works while the PowerManager is active, but there is no advance notice before
the monitor's power is turned off.
Power Indicator Setting
Light off the power indicator. This function is available for the multiple panels settings.
[Procedure]
1. Select <Power Indicator> in the ScreenManager <Others> menu.
2. Select "Disable".
EIZO Logo Appearing Function
When switching on the Power button on the control panel, the EIZO logo is displyed for a while. If you
desire to display or undisplay this logo, use this function. (Default is logo appearing.)
[To undisplay]
Turn off the monitor's power by the Power button, then hold down the Enter button once again and turn the
power back on.
[To display]
Turn off the monitor's power by the Power button, then hold down the Enter button once again and turn the
power back on.