ADC P-61-743 Network Card User Manual


 
ADCP-61-743 Issue 3 September 2004
Page 12
2004, ADC Telecommunications, Inc.
5 CONFIGURATION
Use this menu to view or edit the configuration for the RTAU module after it is installed in the
chassis. This menu can also be used to equip, provision, assign thresholds, and assign service
state.
Note: A “toggle” field type means the user can press the space bar to view and select the
next option that is described; or the user can press the “R” key to view and select the previous
option. An “input” field type means the user must type an entry in the field according to the
parameters described. A “fixed” field is locked and cannot be changed by the user.
Note: Edits can be made in the configuration database in one of two ways: 1) If the
complete field is highlighted, use the space bar to toggle forward or the “R” key to
reverse toggle through the options for that field. 2) If only the first space or the field is
highlighted, type in the data that applies to that field.
Note: Edits can be saved into the configuration database after each change is made in
one of two ways: 1) Press an arrow key and then Enter or Return once; or 2) Press Enter
or Return twice after all selections and entries are made in the screen but before leaving
the screen. If the entries have been accepted, a message “Configuration Successful…
Press Any Key To Continue” will appear on the screen.
Note: Press CONTROL-A for help information on moving around and editing fields.
Note: The RTAU’s status can also be displayed using the Shelf Status screen, where the
letter “R” in the TAU slot column means an RTAU is present. Refer to the Soneplex
System Operation and Maintenance Manual listed under Related Publications at the
beginning of this manual for more information on the Shelf Status screen.
Note: Be sure to configure the line card to be tested before setting up test access.
1. Refer to Figure 3 (shown previously). Check that the STATUS LED on the front panel of
the RTAU module is green, indicating that the module is operating normally.
2. Log on to the Craft Interface. If you are unfamiliar with the log on procedure, refer to the
Soneplex System Operation and Maintenance Manual listed under Related Publications at
the beginning of this manual for more information.
3. Use the arrow or number keys to select System Maintenance from the Main Menu. Press
Enter or Return. The System Maintenance menu will appear as shown in Figure 4.
4. Use the arrow or keyboard keys to select Test Access Unit Commands from the System
Maintenance menu. Press Enter or Return. The RTAU Configuration menu will appear as
shown in Figure 5.
Note: The User Pattern Definition screen is not available for the MPU 5.3 or SCU V3.0
releases.