ADTRAN 1200051L6 Network Card User Manual


 
Chapter 10. Troubleshooting
78
ISU 2x64 Dual Port ISDN Service Unit User Manual 61200051L1-1D
If the Euro ISDN or VN4 switch type is selected, the unit will not enter
the Ready state until a setup message is sent or received (part number
1200051L5 and 1200051L6).
1. Cycle power on the ISU 2x64, leaving it off for a minimum of
2 seconds. Turn the power on for one full minute to ensure
the unit does not read Ready.
2. Disconnect the ISDN line from ISU 2x64. From a functioning
voice phone, call the local directory number(s) provided with
the line. Calling a good ISDN line with nothing connected
usually results in a ring or fast busy tone. If someone an-
swers or you get a not-in-service intercept, there is probably
something wrong with the translation of the line. The phone
service provider should be able to help.
3. If the ISU 2x64 continues to display Link Down, there is a
physical problem with the phone line (more than likely, a
problem with the layer 1 setup). The problem is in one or
more of the following places:
The ISU 2x64 software setup
The ISU 2x64 hardware
The wiring on your premises
The telephone service provider’s wiring
The telephone service provider’s hardware
The telephone service provider’s software setup
To isolate the problem, perform the following procedure:
A. Ensure the ISDN line is plugged into the ISU 2x64 con-
nector marked ISDN IFC on the back of the ISU 2x64.
B. Ensure the ISU 2x64 is configured for dial line service.
C. Try another piece of functioning ISDN equipment on
the line.