Clock Source
•Network
Internal
Diagnostics
Network Loopbacks: Line, payload, remote
Test Pattern Generation and Detection: QRSS, 2
15
- 1, 511, all ones, all zeros
Compliance
EMC - see Electromagnetic Compatibility (EMC) Table on page 6.
AS/ACIF S016
ETSI TBR 12/TBR 13
ACTA/FCC Part 68
IC CS-03
UL/CUL 60950-1
EN 60950-1
IEC 60950-1
AS/NZS 60950-1
RoHS Compliant (1202843E1 only) (Telecommunications exemption)
Environmental
Operating Temperature: 0°C to 50°C
Storage Temperature: -20°C to 70°C
Relative Humidity: 95 percent, noncondensing
Physical
5.63-inch W x 8.63-inch D
T1/E1 Mode DIP Switch
The T1/E1 Wide Module is shipped with the T1/E1 mode switch (located on the circuit board) set to T1. If
you require E1 functionality, use your thumbnail to slide the E1 mode switch to the
ON position (as shown
in the figure below).